Part Numbers and Valve Use
Size 06
Description Part number
M-ZFDRP06A4K0AS/A06 XEB15159-006M01
M-ZFDRP06A4K0AS/A12 XEB15159-002M01
M-ZFDRP06A4K0AS/A15 XEB15159-001M01
M-ZFDRP06A4K0AS/A20 XEB15159-007M01
M-ZFDRP06A4K0AS/A25 XEB15159-008M01
Check valve opening pressure is 0.3 bar; The number at the end of the description (AXX)
indicates the size of the throttling orifice in 1/10th mm. Example: A15 = 1.5mm orifice in A.-
Size 10
Description Part number
M-ZFDRP10A4K0AS/
CEE10;A20
XEB17522-004M01
M-ZFDRP10A4K0AS/
CEE10;A25
XEB17522-005M01
M-ZFDRP10A4K0AS/
CEE10;A30
XEB17522-006M01
M-ZFDRP10A4K0AS/
CEE10;A35
XEB17522-003M01
M-ZFDRP10A4K0AS/
CEE10;A40
XEB17522-002M01
Check valve opening pressure is 0.3 bar; the number at the end of the description (Axx)
indicates the size of the throttling orifice in 1/10th mm. Example: A15 = 1.5mm orifice in A. -
Seal materials - ZFDR valves are available in the following seal combinations:
N = NBR (Nitrile Butadiene Rubber) T = NBR + PU (Polyurathane Elastomer)
V = FKM (Fluorelastomer, Vition ) M = FKM + PU
Please use the first letter of the description to indicate the desired seal configuration.
®
Valve Use
In the example shown, an accumalator is
isolated using a position monitored active
cartridge.
The D2 orifice of the ZFDR valve limits the
the opening speed of the cartridge.
The closing speed is determined by the
size of the D1 orifice.
Note: when configuring a setup like this,
please take into consideration the balance of
forces acting on the cartridge poppet.
For further assistance please contact us.
system